Repair

We do provide “Repairing service + Calibration adjustment”, including of parts replacement and accuracy checking.
You are welcome to contact us through Whatsapps or Wechat or Phone call for further information.
 
Contact Information :
Whatapps        : +6016-6048808
Wechat            : BryanSoon1009
Mobile             : +6016-6048808


Our Repairing & Service Job Scope:

 * Metrology Stamping for Weighing Scales / Metrology Stamping untuk Alat Timbang.


  1. MITUTOYO Measuring Instruments,
  • Accuracy adjustment, replacing new parts, travelling of movement guide/screw shaft, display faulty, cleaning & servicing. ​
  • 293 Series Digimatic Micrometer
  • 570  Series Digimatic Height Gage
  • 500 Series Digimatic Caliper
  • 568 Series Borematic
  • 368 Series Holtest
  • 468 Series Digimatic Holtest
  • 547 Series Thickness Gage
  • 543 Series Digimatic Indicator
 
  1. Profile Projector / Video Measuring Scope
  • Inaccurate reading.
  • Replacing of linear scale, cross roller guide & Display Reading Unit.
  • Measuring stage levelling issue.
  • Replacing of new objective lens.
  • Calibration adjustment.
 
  1. Weighing Instruments :
  • Weighing Scale, Floor Scale, Conveyor Scale & Analytical Balance.
  • Replacing new load cell, display panel & keypad.    
  • Replacing weighing indicator, cable & junction card.
  • Accuracy check and calibration adjustment.
  • Metrology stamping service.
 


  1. Rockwell Hardness Tester
  • Reading inaccurate.
  • Accuracy compensate adjustment.
  • Replacing of Indicator Bridge & bearing.
  • Pre-load setting stuck, replacing Dial Gauge & lever set amplifier.
 
  1. Humidity Chamber:
  • Inaccurate of humidity reading, dry wet bulb temperature humidity sensor setting issue.
  • Failure on cooling function. 
  • Power trip while operation reach up to certain point of  low temperature.
  • Replacing new cooling compressor.
  • Humidity function failure, no mist out from nozzle while operation.
  • Compressor overload / overpressure.
 
  1. Oven / Water Bath
  • Inaccurate of temperature reading at different position point.
  • Replacing a blower for ventilation & circulation features.
  • Replacing heater.
  • Can’t power on issue.
  • Retrofit Memmert / Binder used oven by installing new Autonic Temperature & Timer Controller .
 
  1. Electrical & Electronic Equipment’s with Motor
  • Can’t power on issue.
  • Replacing of internal IC chips.
  • Replacing of display screen.
  • Replacing rechargeable battery.
  • Replacing sensor.
 
  1. Taber Type Abrasion Tester
  • Rotating disc lack of balance, replacing of shaft & screw.
 


  1. MTS Universal Tensile Tester
  • Connection error between computer and machine.
  • Replacing Interface Controller.
  • Replacing new load cell.
  • Upgrade new software.
 
  1. Teclock Durometer
  • Reading out of accuracy.
  • Mechanism calibration adjustments.
 
  1. Ozone Aging Test Chamber
  • Ozone concentration (pphm) of the chamber not match with what had set.
  • Tuning back by adding an amp controller over the circuit.
  • Ozone generator broken, replace a new ozone generator.
  • Calibration adjustment. 
 
  1. Stereo Microscope
  • Cleaning lens to remove any lingering dirt or particles.
 
  1. Repair Industrial Inverter
  • Brand as mentioned:
  • ABB, Allen Bradley, Fuji Electric, Mitsubishi, Omron, Siemens, GE Fanuc, Delta, Rhymebus, Dirise, Toshiba, Lenze, Danfoss, Hitachi, Yaskawa, Teco…
 
 


Switch to Mobile Version
Recent Updates