Sealing Laboratory Sealer Gradient Laboratory Film Five Points Heat Seal Tester Testing

Previous 24 / 30 Next

Sealing Laboratory Sealer Gradient Laboratory Film Five Points Heat Seal Tester Testing Packaging Flim & Paper Board Testing


Sealing Laboratory Sealer Gradient Laboratory Film Five Points Heat Seal Tester Testing
Model: CY518B
 
Quick Details:

Power : Electronic
Heat Seal Area : 40 mm x 10 mm x 5
Room Temperature : 300¡æ
Accuracy : ±1¡æ
Time : 0.1-999.9s
Pressure : 0.05-0.7Mpa
Standard : ASTM F2029
Test Start Mode : Manual and footswitch
Power Supply : 220V 50Hz
 
Product Description:
It is professionally designed for the determination of heat sealability of plastic films, composite films, coated paper, and other sealing films under certain sealing speed, pressure and 5 different temperatures. The heat sealability of heat sealing materials would be greatly affected by the factors of melting point, thermal stability, fluidity and thickness. The properest heat sealability parameters could be obtained accurately and efficiently through this instrument.
 
Standards:
ASTM F2029, QB/T 2358, YBB 00122003
 
Features:

  1. Digital P.I.D. temperature control technology ensures preset temperature to be reached rapidly without any fluctuation.
  2. Wide range control of temperature, pressure and time could meet various test conditions.
  3. Manual or pedal switch control, as well as the anti-scald design, provides a convenient and safe operating environment.
  4. The instrument is controlled by micro-computer with LCD, PVC operation panel, and menu interface, which is convenient for customers.
  5. Upper sealing jaws are individually controlled by 5 gas cylinders which ensure the stability of the heat sealing process.
  6. The heating tube joints can be easily installed or removed for rapid replacement.
  7. Independent temperature control of upper and lower sealing jaws gives multiple combinations of test conditions.
 
Technical Specifications

Sealing Temperature : Room temperature ~ 250°C
Sealing Presre : 0.1 MPa ~ 0.7 MPa
Dwell Time : 0.1~999.9 s
Temperature Accuracy : ±0.2°C
Temperature Gradient : ≤20°C
Gas Supply Pressure : 0.1 MPa ~ 0.7 MPa (outside of supply scope)
Port Size :  Φ8 mm PU Tubing
Sealing Area : 40 mm x 10 mm x 5
Dimension : 576 mm (L) x 430 mm (W) x 510 mm (H)
Power Supply : AC 220 V 50 Hz
 